PI普爱 G-902.R1I001 ACS驱动模块
PI普爱 G-902.R1I001 ACS驱动模块
用于4个驱动轴,带交流伺服电机、直流电机、音圈电机、步进电机



通信
通过以太网TCP/IP和RS-232接口与PC通信。EtherCAT接口,用于集成EtherCAT网络中。通过EtherCAT主站进行命令控制。
规格
G-902.R1I001 / G-902.R2I001 |
|
---|---|
Function |
ACS driver module IDMsm with connectors for positioners from PI |
Design |
19-inch rack mount housing |
Motor types |
2-phase and 3-phase AC servo motors / brushless DC motors, brushed DC motors, voice coil motors, stepper motors |
Number of drive axes |
4 |
Motion and Control |
G-902.R1I001 / G-902.R2I001 |
---|---|
Sample/Update rate of control loop |
20 kHz position 20 kHz velocity 20 kHz current |
Control algorithms |
Cascading PIVFF controller structure with loop-shaping filters Velocity feedforward MIMO (Multiple Input Multiple Output) gantry control algorithm Dual-loop control Disturbance rejection Gain scheduling Field-oriented control Space vector modulation |
Profile generation |
3rd order with uniform endpoint modification during operation |
Encoder |
1 × per axis, supported types: Incremental: 1 Vpp, RS-422 Absolute: BiSS-C, EnDat 2.1 & 2.2, Smart-Abs, SSI, Sanyo-Denki, Panasonic A6 |
Limit switches |
2 × per axis Default: 5 V sinking (NPN) Optional configuration: 24 V; sourcing (PNP) |
Reference switch |
Default: 1 × per axis, 5 V sinking (NPN) Optional configuration: 24 V; sourcing (PNP); use as digital multipurpose inputs on digital I/O connector (HD D-sub 15 (f)) |
Motor brake |
1 × per axis Integrated PWM brake driver with current reduction for reduced brake heating |
Functional safety |
STO (safe torque off): Electrical interface: two-channel input, 24 V, insulated Safety standards: EN/IEC 61800-5-2 Ed. 2 (second environment) EN/IEC 61800-5-1 IEC 61508 IEC 62061 PLe performance level and category 3 according to: EN ISO 13849-1/-2 SS1 (safe stop 1): Braking time until STO activation: 110-230 ms The exact value for the braking time is a fixed value (SS1-t functionality) and depends on the product configuration. |
Electrical Properties |
G-902.R1I001 |
G-902.R2I001 |
---|---|---|
Intermediate circuit voltage |
48 V |
48 V |
Output power intermediate circuit, continuous / peak (max. 10 s) |
550 W / 550 W at 40 °C |
1000 W / 1200 W at 40 °C |
Output power per axis (effective value), continuous / peak (max. 1 s) |
186 W* / 363 W* |
186 W / 363 W |
Current limitation per motor phase (sine amplitude), continuous / peak (max. 1 s) |
5 A / 10 A |
5 A / 10 A |
Interfaces and Operation |
G-902.R1I001 / G-902.R2I001 |
---|---|
Motor connector |
4 × HD D-sub 26 (f) |
Sensor connector |
4 × HD D-sub 26 (f) or via the motor connectors Connector selection per axis via DIP switch |
Digital inputs |
Default: 4 × NPN 5 V sinking for reference switches on the motor and encoder connectors Optional configuration: Up to 4 multipurpose inputs, PNP 24 V source, parallel on 2 × HD D-sub 15 (f) |
Digital outputs |
2 × HD D-sub 15 (f): 4 × output PNP 24 V source; used for controlling the brake drivers D-sub 25 (f): 8 × multipurpose output, differential (RS-422) |
Analog inputs / outputs |
HD D-sub 15 (m): 2 differential analog inputs: ±10 V, 12 bit 2 differential analog outputs: ±10 V, 10 bit |
Outputs for position event generator (PEG) |
Parallel on HD D-sub 15 (m) and HD D-sub 15 (f): 4 differential outputs (RS-422) for pulses at programmable positions, pulse width 27 ns to 1.745 ms, max. 10 MHz; only possible with incremental encoder |
Inputs for STO safety function |
D-sub 9 (f): 2 inputs (STO1, STO2): 24 V, up to 50 mA per STO input, with an inrush current of less than 70 mA |
LEDs |
Status of the fuses for the 24 V power supply, STO signals, logic supply |
Communication interfaces |
EtherCAT IN and OUT: RJ-45 Ethernet (TCP/IP, Ethernet/IP, Modbus/TCP): RJ-45 RS-232: D-sub 9 (m) |
User software |
ACS SPiiPlus MMI Application Studio |
Application programming interfaces |
Programming libraries for C/C++, COM, .NET, MATLAB available |
Programming |
ACSPL+ real-time script language: up to 4 simultaneously running programs (buffers) |
Miscellaneous |
G-902.R1I001 / G-902.R2I001 |
---|---|
Operating voltage |
100-240 V AC, 50-60 Hz |
Required fusing per mains supply line |
IEC: 12-16 A at 250 V AC; 50 Hz UL/CSA: 12-20 A at 125/250 V AC; 60 Hz |
Operating temperature range |
5 to 40 °C (temperature protection switches off at excessively high temperatures) |
Mass |
10 kg |
Dimensions |
482.6 mm × 533.75 mm × 95.3 mm (including handles) |
手机/微信:13242449659电话:0755-89355351 QQ:842471885 邮箱:842471885@qq.com